TPM Instrumentation
Rich Neswold
P.O. Box 500
Mail Stop 347
Batavia, IL 60510
+1 630 840-3454
$Date: 1999/12/06 20:23:24 $
Contents
- Introduction
- Instrumentation Tables
1.
Introduction
The telescope performance monitor (TPM) monitors many telescope
parameters during a night's observation. These parameters are
dumped into a log file on APO's Unix box. To make it easier for
operators to refer to specific parameters, names have been
designated for each data point. This document describes the
name-to-parameter mapping.
2.
Instrumentation Tables
- 2.1. Altitude-Related Instrumentation
- 2.2. Azimuth-Related Instrumentation
- 2.3. Rotator-Related Instrumentation
- 2.4. Environmental Instrumentation
- 2.5. Mirror Instrumentation
- 2.6. Miscellaneous Instrumentation
These tables are a work-in-progress. As new instrumentation
gets added (or removed), these tables will be updated
appropriately.
The tables use a color coding to reflect the state of
support. The colors are defined to be:
Color |
Description |
|
Has TPM support and is enabled by default. |
|
Has TPM support but isn't enabled by default. |
|
No TPM support yet. |
2.1.
Altitude-Related Instrumentation
Table 1:
Altitude-Related Instrumentation
Name |
Description |
Device Type |
Input Type |
Sample Rate (Hz) |
ALCPOS |
Altitude Position Command from MCP |
Memory |
Digital |
200 |
ALCVOLT |
Altitude Voltage Command from MCP |
Memory |
Digital |
20 |
ALENC1 |
Altitude Position Encoder 1 |
Encoder |
Digital |
33 |
ALENC2 |
Altitude Position Encoder 2 |
Encoder |
Digital |
33 |
ALICHG |
Altitude Instrument Change Position |
SPST |
Digital |
200 |
ALLWC |
Altitude Windscreen Collision (Lowering) |
SPST |
Digital |
0.2 |
ALMCPPOS |
|
Memory |
Digital |
20 |
ALMCPVEL |
|
Memory |
Digital |
20 |
ALMCPTIM |
|
Memory |
Digital |
20 |
ALMTRC1 |
Altitude Motor Current (Sensor 1) |
Sensor |
Analog |
33 |
ALMTRC2 |
Altitude Motor Current (Sensor 2) |
Sensor |
Analog |
33 |
ALMTRV1 |
Altitude Motor Voltage (Sensor 1) |
Sensor |
Analog |
33 |
ALMTRV2 |
Altitude Motor Voltage (Sensor 2) |
Sensor |
Analog |
33 |
ALP-2 |
Altitude -2° Position |
SPST |
Digital |
0.2 |
ALP100 |
Altitude 100° Position |
SPST |
Digital |
0.2 |
ALP20 |
Altitude 20° Position |
SPST |
Digital |
0.2 |
ALRWC |
Altitude Windscreen Collision (Raising) |
SPST |
Digital |
0.2 |
ALSTATE |
|
Memory |
Digital |
1 |
ALSTOW |
Altitude ``Stow'' Position |
SPST |
Digital |
1 |
ALTCCPOS |
|
Memory |
Digital |
20 |
ALTCCVEL |
|
Memory |
Digital |
20 |
ALTCCTIM |
|
Memory |
Digital |
20 |
ALWSPOS |
Altitude-to-Windscreen Position |
LVDT |
Analog |
10 |
2.2.
Azimuth-Related Instrumentation
Table 2:
Azimuth-Related Instrumentation
Name |
Description |
Device Type |
Input Type |
Sample Rate (Hz) |
AZCPOS |
Azimuth Position Command from MCP |
Memory |
Digital |
200 |
AZCVOLT |
Azimuth Voltage Command from MCP |
Memory |
Digital |
20 |
AZCCWC |
Azimuth Counter-Clockwise Windscreen Collision |
SPST |
Digital |
0.2 |
AZCCWHL |
Azimuth Counter-Clockwise Hard Limit |
SPST |
Digital |
0.2 |
AZCCWSL |
Azimuth Counter-Clockwise Soft Limit |
SPST |
Digital |
0.2 |
AZCWC |
Azimuth Clockwise Windscreen Collision |
SPST |
Digital |
0.2 |
AZCWHL |
Azimuth Clockwise Hard Limit |
SPST |
Digital |
0.2 |
AZCWSL |
Azimuth Clockwise Soft Limit |
SPST |
Digital |
0.2 |
AZENC1 |
Azimuth Position Encoder 1 |
Encoder |
Digital |
33 |
AZENC2 |
Azimuth Position Encoder 2 |
Encoder |
Digital |
33 |
AZICHG |
Azimuth Instrument Change Position |
SPST |
Digital |
0.2 |
AZMCPPOS |
|
Memory |
Digital |
20 |
AZMCPVEL |
|
Memory |
Digital |
20 |
AZMCPTIM |
|
Memory |
Digital |
20 |
AZMTRC1 |
Azimuth Motor Current (Sensor 1) |
Sensor |
Analog |
33 |
AZMTRC2 |
Azimuth Motor Current (Sensor 2) |
Sensor |
Analog |
33 |
AZMTRV1 |
Azimuth Motor Voltage (Sensor 1) |
Sensor |
Analog |
33 |
AZMTRV2 |
Azimuth Motor Voltage (Sensor 2) |
Sensor |
Analog |
33 |
AZSTATE |
|
Memory |
Digital |
1 |
AZTCCPOS |
|
Memory |
Digital |
20 |
AZTCCVEL |
|
Memory |
Digital |
20 |
AZTCCTIM |
|
Memory |
Digital |
20 |
AZWSPOS |
Azimuth-to-Windscreen Position |
LVDT |
Analog |
0.2 |
2.3.
Rotator-Related Instrumentation
Table 3:
Rotator-Related Instrumentation
Name |
Description |
Device Type |
Input Type |
Sample Rate (Hz) |
ROCPOS |
Rotator Position Command from MCP |
Memory |
Digital |
200 |
ROCVOLT |
Rotator Voltage Command from MCP |
Memory |
Digital |
20 |
ROCCWHL |
Rotator Counter-Clockwise Hard Limit |
SPST |
Digital |
0.2 |
ROCCWSL |
Rotator Counter-Clockwise Soft Limit |
SPST |
Digital |
0.2 |
ROCWHL |
Rotator Clockwise Hard Limit |
SPST |
Digital |
0.2 |
ROCWSL |
Rotator Clockwise Soft Limit |
SPST |
Digital |
0.2 |
ROENC |
Rotator Position Encoder |
Encoder |
Digital |
33 |
ROICHG |
Rotator Instrument Change Position |
SPST |
Digital |
0.2 |
ROMCPPOS |
|
Memory |
Digital |
20 |
ROMCPVEL |
|
Memory |
Digital |
20 |
ROMCPTIM |
|
Memory |
Digital |
20 |
ROMTRC |
Rotator Motor Current |
Sensor |
Analog |
33 |
ROMTRV |
Rotator Motor Voltage |
Sensor |
Analog |
33 |
ROSTATE |
|
Memory |
Digital |
1 |
ROTCCPOS |
|
Memory |
Digital |
20 |
ROTCCVEL |
|
Memory |
Digital |
20 |
ROTCCTIM |
|
Memory |
Digital |
20 |
2.4.
Environmental Instrumentation
Table 4:
Environmental-Related Instrumentation
Name |
Description |
Device Type |
Input Type |
Sample Rate (Hz) |
TEMP |
Temperature |
Sensor |
Analog |
1 |
WNDDIR |
Wind Direction |
Sensor |
Analog |
200 |
WNDSPD |
Wind Speed |
Sensor |
Analog |
200 |
2.5.
Mirror Instrumentation
Table 5:
Mirror-Related Instrumentation
Name |
Description |
Device Type |
Input Type |
Sample Rate (Hz) |
AXBELLPR1 |
Axial Bellofram Pressure 1 |
Sensor |
Analog |
10 |
AXBELLPR2 |
Axial Bellofram Pressure 2 |
Sensor |
Analog |
10 |
AXBELLPR3 |
Axial Bellofram Pressure 3 |
Sensor |
Analog |
10 |
AXERROR1 |
Axial Pressure Error 1 |
Sensor |
Analog |
10 |
AXERROR2 |
Axial Pressure Error 2 |
Sensor |
Analog |
10 |
AXERROR3 |
Axial Pressure Error 3 |
Sensor |
Analog |
10 |
AXLOAD1 |
Axial Load Cell 1 |
Sensor |
Analog |
10 |
AXLOAD2 |
Axial Load Cell 2 |
Sensor |
Analog |
10 |
AXLOAD3 |
Axial Load Cell 3 |
Sensor |
Analog |
10 |
AXLVDT1 |
Axial LVDT 1 |
Sensor |
Analog |
10 |
AXLVDT2 |
Axial LVDT 2 |
Sensor |
Analog |
10 |
AXLVDT3 |
Axial LVDT 3 |
Sensor |
Analog |
10 |
AXPRES1 |
Axial Pressure Command 1 |
Sensor |
Analog |
10 |
AXPRES2 |
Axial Pressure Command 2 |
Sensor |
Analog |
10 |
AXPRES3 |
Axial Pressure Command 3 |
Sensor |
Analog |
10 |
AXVALVE1 |
Axial Pressure Valve 1 |
Sensor |
Analog |
10 |
AXVALVE2 |
Axial Pressure Valve 2 |
Sensor |
Analog |
10 |
AXVALVE3 |
Axial Pressure Valve 3 |
Sensor |
Analog |
10 |
TRBELLPR |
Transverse Bellofram Pressure |
Sensor |
Analog |
10 |
TRERROR |
Transverse Pressure Error |
Sensor |
Analog |
10 |
TRLOAD |
Transverse Load Cell |
Sensor |
Analog |
10 |
TRLVDT |
Transverse LVDT |
Sensor |
Analog |
10 |
TRPRES |
Transverse Pressure Command |
Sensor |
Analog |
10 |
TRVALVE |
Transverse Pressure Valve |
Sensor |
Analog |
10 |
2.6.
Miscellaneous Instrumentation
Table 6:
Miscellaneous Instrumentation
Name |
Description |
Device Type |
Input Type |
Sample Rate (Hz) |
MIG1 |
MIG Input #1 |
Sensor |
ASCII |
1 |
MIG2 |
MIG Input #2 |
Sensor |
ASCII |
1 |
MIG3 |
MIG Input #3 |
Sensor |
ASCII |
1 |
MIG4 |
MIG Input #4 |
Sensor |
ASCII |
1 |
MIG5 |
MIG Input #5 |
Sensor |
ASCII |
1 |
MIG6 |
MIG Input #6 |
Sensor |
ASCII |
1 |
MIG7 |
MIG Input #7 |
Sensor |
ASCII |
1 |
MIG8 |
MIG Input #8 |
Sensor |
ASCII |
1 |
|